Algorithm for constructing a three-dimensional model of an ultrasonic flowmeter for its CFD analysis
Abstract
The authors of the paper have developed a step-by-step algorithm for constructing a three-dimensional model of an ultrasonic flowmeter in the CAD system SolidWorks for its CFD analysis. This algorithm is a component of the generalized procedure for CFD analysis of ultrasonic flowmeters. Based on this algorithm, the authors have demonstrated the calculation of important parameters of a two-path chordal ultrasonic flowmeter from a design standpoint, when building its three-dimensional model in the SolidWorks CAD system. For the two-path chordal ultrasonic flowmeter in the example provided in the paper, the authors obtained two calibration curves – for air and methane
References
2. International Organization for Standardization (ISO). (2010). Measurement of fluid flow in closed conduits – Ultrasonic meters for gas. Part 1: Meters for custody transfer and allocation measurement (ISO 17089-1:2010). Geneva.
3. Groupe Europeen de Recherches Gazieres (GERG). (2000). GERG Project on ultrasonic gas flow meters, Phase II (Technical Monograph TM 11). Brussels.
4. American Gas Association (AGA). (2003). Measurement of gas by multipath ultrasonic meters (2nd ed.) (Technical Report No. 9). Washington.
5. Research & Engineering Centre BP International Ltd. (Ed.). (1995). Installation effects on multi-path ultrasonic flow meters (Technical Report EUR 16175 EN). Sunbury, UK.
Abstract views: 51 PDF Downloads: 40