Improving of the software for calculating the location coordinates and weighting coefficients of acoustic paths of ultrasonic flow meters

Keywords: software, ultrasonic flow meter, acoustic paths, chordal scheme, numerical integration methods

Abstract

Based on new numerical integration method, a software is improved, which allows you to calculate the location coordinates and weighting coefficients of acoustic paths of multipath chordal ultrasonic flow meters. The software makes it possible to simplify the process of designing new designs of multipath chordal ultrasonic flow meters.

References

International Organization for Standardization. (2010). ISO 17089-1: Measurement of fluid flow in closed conduits – Ultrasonic meters for gas. Part 1: Meters for custody transfer and allocation measurement. Geneva, Switzerland: ISO.
2. Pannel, C.N., Evans, C.N., and Jackson, D.A. (1990). A new integration technique for flowmeters with chordal paths. Flow Measurement Instrumentation, 1, 216-224.
3. Voser, A. (1999). Analysis and error optimization of multipath strength acoustic flow measurement in water turbines. Unpublished master‘s doctoral dissertation, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland.
4. Tresch, T., Gruber, P., and Staubli, T. (2006, July 30 – August 1). Comparison of integration methods for multipath acoustic discharge measurements. Paper presented at the Proceedings of VI International Conference on IGHEM, Portland Oregon, USA.
5. Abramovitz, M., and Stegum, I. (1964). Handbook of mathematical function. New York, NY: NBS.

Abstract views: 98
PDF Downloads: 74
Published
2023-04-01
How to Cite
Roman , V., & Iliuchok, V. (2023). Improving of the software for calculating the location coordinates and weighting coefficients of acoustic paths of ultrasonic flow meters. COMPUTER-INTEGRATED TECHNOLOGIES: EDUCATION, SCIENCE, PRODUCTION, (50), 157-162. https://doi.org/10.36910/6775-2524-0560-2023-50-24
Section
Telecommunications and radio engineering